This highly detailed repair manual covers all repairs and servicing. All technical details taken directly from the manufacturer can be found in this manual, It is the factory manual from the manufacturer. Linde Pallet Stacker Series 362 Explosion Protected: T20 Ex, T30 Ex service repair manual is the same manual used by professional technicians, mechanics and workshops around the world.

 

Linde Pallet Stacker Series 362 Explosion Protected: T20 Ex, T30 Ex service repair manual has easy to read text sections with top quality diagrams and instructions, will guide you through fundamentals of maintaining and repairing, step-by-step, to teach you what the factory trained technicians already know by heart. For that reason, you will not find it difficult to repair or to maintain some of the innovative features loaded on the vehicle when you have the manual. Using this repair manual is the true way to keep your vehicle working properly.

 

 

Model Covers:

T20 Ex
T30 Ex

 

Service Repair Manual Covers:

General information
Rules
Inspections of explosion-protected systems and industrial trucks certified by PTB
according to ELEX-V
Inspections of explosion-protected systems and industrial trucks certified acc. to directive 94 / 9 / EC
Explosion protection measures on the truck
Battery
Drive wheel
Brake
Forks
Electrical installation
Instruments
Torque settings for screws used with flameproof enclosure covers
Special tools
1. Drive – Motor
1.1 Drive motor
1.1.1 Technical data
1.2 General information
1.3 Inspection and replacement of the motor brushes
1.3.1 Drive motor installation
3. Chassis
3.1 Load wheel system
3.2 Castorwheel
3.2.1 Height adjustment
4. Steering system and wheels
4.1 Drive wheel
4. 1. 1 Checking the drive wheel leakage resistance
5 Controls
5.1 Traction control
5.1.1 Lift control
6 Electrical system
6.1 Flameproof enclosures
6.1.1 Maintenance of flameproof enclosures
6.1.2 Control enclosure
6.1.3 Checking the PG glands
6.1.4 Checking electric cables for tightness and condition
6.2 Checking the electrical system insulation resistance
6.2.1 Ex insulation monitoring procedures and determinatin of limits
6.2.1.1 General information
6.2.2 Insulation monitor (94/9/EC)
6.2.2.1 Checking insulation monitor 1A2
6.2.2.2 Insulation monitor circuit diagram
6.2.3 Insulation resistance test
6.3 Intrinsically-safe circuits
6.4 Operation and description of switch amplifiers (ELEX-V version)
6.4.1 General schematic diagram of a switch amplifier
6.4.2 Functional test of switch amplifiers
6.5 Operation and description of switch amplifiers (94/9/EC version)
6.5.1 General schematic diagram of a switch amplifier
6.5.2 Functional test of switch amplifiers
6.6 Renewal of switch amplifiers (ELex-V and 94/9EC)
6.7 Operation and description of Zener barriers (ELEX-V version)
6.7.1 Terminal designations of Zener barriers
6.7.2 General schematic diagram of Zener barriers
6.8 Operation and description of Zener barriers (94/9EC version)
6.8.1 Terminal designations of Zener barriers
6.8.2 General schematic diagram of Zener barriers
6.9 Checking the Zener barrier internal resistors
6.10 Power supply
6.11 Monitoring unit V4
6.12 Wiring diagrams
6.12.1 T20/30 EX with mechanical brake according to ELEX-V
6.12.1.1 Intrinsically-safe circuits of T20/T30 EX with mechanical brake according to ELEX-V
6.12.1.2 Terminal strip X1 – Non-intrinsically-safe circuits
6.12.2 T20/30 EX with electric brake according to ELEX-V
6.12.2.1 Intrinsically-safe circuits of T20/T30 EX with electric brake according to ELEX-V
6.12.2.2 Terminal strip X2 – Non-intrinsically-safe circuits
6.12.3 T20/30 EX with electric brake according to ELEX-V with ATEX composite instrument
6.12.3.1 Intrinsically-safe circuits of T20/T30 EX with electric brake according to ELEX-V with ATEX composite instrument
6.12.3.2 Terminal strip X2 – Non-intrinsically-safe circuits
6.12.4 T20/30 EX with electric brake according to 94/9/EC (ATEX 100A) with ATEX composite instrument and insulation monitor
6.12.4.1 Intrinsically-safe circuits of T20/30 EX with electric brake acc. To 94/9/EC (ATEX 100A) with composite instrument and insulation monitor
6. 1 2.4.2 Insulation monitor of T20/30 EX with electric brake according to 94/9/EC (ATEX 100a)
6.12.4.3 Terminal strip X2 – Non-intrinsically-safe circuits
6.12.4.4 Terminal strip X3 – Intrinsically-safe circuits
6.13 Representation of some EX relevanten components
6.14 Representation of components in control enclosure
7 Pump motor – Hydraulic system
7.1 Technical data
7.2 Motor brush inspection and replacement
7.2.1 Pump unit removal and installation
More Theres——–

 

============
** Total Pages: 105
** File Format: PDF
** Language: English
** Requirements: Adobe PDF Reader & WinZip
** Compatible: All Versions of Windows & Mac, Linux OS, Iphone, Ipad, Android etc…

 

NO waiting! You will have instant access to your download! All pages are printable, No shipping fee, No waiting nervously for the postal delivery, you can start doing your repairs right away!

We will always try to get the full satisfaction of our customers. Even after you have purchased this manual, we will pay full attention to any issues, regardless of the nature of the situation.

 

THE DOWNLOAD LINK WILL ALSO BE SENT TO YOUR E-MAIL.

 

So please make sure your email address is correct. Don’t Forget to Check Spam / Junk if can’t find the new message in your email inbox immediately.

 

Any questions please contact: admin@servicemanualperfect.com

Thanks for visiting!